Car parking norms in Hyderabad

Governing regulation

Telangana Building Rules 2012 (adopted from AP Building Rules 2012, G.O.Ms.No.168)

Rule 12 — Parking requirements (percentage of built-up area), GHMC column

Sanctioning authority

Greater Hyderabad Municipal Corporation (GHMC) / HMDA

Mechanical parking

Permitted with conditions

See conditions ↓

Verification

28 Sep 2026

8 rows verified

Requirement

How much parking is required

Rule 12 — Parking requirements (percentage of built-up area), GHMC column

Applies to Requirement Two-wheelers Visitor Mechanical Clause · verified
Residential
Apartment complexes 30% of total built-up area as parking — — Permitted Telangana Building Rules 2012 (G.O.Ms.No.168), Rule 12, parking table — GHMC column
✓ Sep 2026
Hospital
All 30% of total built-up area as parking — — Permitted Telangana Building Rules 2012 (G.O.Ms.No.168), Rule 12, parking table — GHMC column
✓ Sep 2026
Institutional / educational
Schools, colleges, other educational 30% of total built-up area as parking — — Permitted Telangana Building Rules 2012 (G.O.Ms.No.168), Rule 12, parking table — GHMC column
✓ Sep 2026
Industrial / godowns
All 30% of total built-up area as parking — — Permitted Telangana Building Rules 2012 (G.O.Ms.No.168), Rule 12, parking table — GHMC column
✓ Sep 2026
Commercial / business
Hotels, restaurants, lodges, cinema halls, offices, kalyana mandapams, non-residential high-rise 40% of total built-up area as parking — — Permitted Telangana Building Rules 2012 (G.O.Ms.No.168), Rule 12, parking table — GHMC column
✓ Sep 2026
Shopping malls
Above 4,000 sqm 60% of total built-up area as parking — — Permitted Telangana Building Rules 2012 (G.O.Ms.No.168), Rule 12, parking table — GHMC column
✓ Sep 2026
IT / ITES complexes
All 60% of total built-up area as parking — — Permitted Telangana Building Rules 2012 (G.O.Ms.No.168), Rule 12, parking table — GHMC column
✓ Sep 2026
Multiplexes
All 60% of total built-up area as parking — — Permitted Telangana Building Rules 2012 (G.O.Ms.No.168), Rule 12, parking table — GHMC column
✓ Sep 2026

Mechanical parking

Permitted with conditions in Hyderabad

What the regulation says

Hyderabad expresses the requirement as a percentage of total built-up area, not a count of bays. Parking may be provided in basements or cellars, stilts and upper floors; mechanical and multi-level systems are accepted where the parking plan shows the required area equivalence.

Conditions to design around

• The requirement is an AREA: GHMC column — residential 30%, commercial/business/hotels 40%, malls (> 4,000 sqm) and IT/ITES complexes 60%, multiplexes 60% of total built-up area. • Mechanical systems must demonstrate equivalent capacity; the area-per-car equivalence is agreed with GHMC at scrutiny — get it in writing. • Fire NOC for buildings above 15 m; parking floors inside the fire-tender path are not permitted. • Visitor parking is included within the percentage (HMDA guidance cites 22% incl. visitors for certain layouts).

Dimensions

Bay sizes and geometry

Bay type Width Length Note
Car bay (rules reference NBC) 2.5 m 5 m Confirm against Rule 12 annexure

Driveways, ramps and headroom

Stilt parking permitted; basements/cellars for parking only. Parking-floor height and ramp gradient follow NBC 2016.

Headroom and structural requirements

Follow NBC 2016 for clear heights; mechanical systems sized per the sanctioned plan.

Provisions

Loadings, relaxations and clearances

Visitor parking

Included in the percentage requirement.

Two-wheelers and other vehicles

Not separately counted — the percentage covers all vehicles.

Relaxations and special cases

Lower percentages apply outside GHMC (HMDA municipalities 20–50%; other corporations 20–30%) — the table has seven authority columns.

Fire clearances

Telangana Fire Services NOC above 15 m; TS Fire Service Act provisions apply to parking structures.

Change log

Amendments since verification

  1. No amendments recorded since verification.

Record verified 28 Sep 2026 by WAP-AE desk verification 22-Sep-2026 · Telangana Building Rules 2012 (adopted from AP Building Rules 2012, G.O.Ms.No.168) , G.O.Ms.No.168 MA&UD dated 7 Apr 2012, as adopted and amended by Telangana . Read the regulation ↗

Can your plot meet this norm?

Send us the plot dimensions and available headroom. We will return a yield study showing how many bays Hyderabad's requirement needs, how many the site gives conventionally, and how many it gives mechanically. Free, within seventy-two hours.

Request a free yield audit

This page is a reference, not a sanction. Parking requirements change and are applied with local discretion; cite the authority document, not this summary, and confirm the current position with the sanctioning authority before making a submission. WAParking accepts no liability for reliance on this summary.